HP/Agilent 3585A 20 Hz-40 MHz High Performance Spectrum Analyzer

HP/Agilent 3585A 20 Hz-40 MHz High Performance Spectrum Analyzer

USD 2499.99 USD
SKU: 6bqjb1j0
Condition: Used

Specifications

All Returns AcceptedReturnsNotAccepted
Frequency Range20 Hz - 40 MHz
Model3585A
MPN3585A

HP/Agilent 3585A 20 Hz-40 MHz High Performance Spectrum Analyzer Comes with what you see in the pictures. If you don't see it, you probably won't get it. Specifications are from HP/Agilent/Keysight and may vary slightly due to upgrades, options, or revisions this unit may or may not have. The unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight. The rackmount kit is not included! The Unit's Serial Number Tag Reads: Serial Number: 1750A01931 Key Features: 80 dB dynamic range 3 Hz resolution bandwidth ±0.4 dB amplitude accuracy 1001 x 1024 Digital Storage Display Description: The HP 3585A Spectrum Analyzer delivers high performance where it coutns - at baseband frequencies. With unmatched accuracy, resolution, and dynamic range, the HP 3585A is HP's best solution for signal analysis at the critical frequencies comprimising voice, picture, or digital information. In today's high speed, high density information processing systems, maintaining the integrity of data signals requires more measurement performance than ever before. The 3585A provides 80 dB of spurious-free dynamic range, a sharp 3 Hz resolution bandwidth, and fully synthesized tuning. Its 20 Hz - 40.1 MHz frequency range is more than adequate to cover most information bandwidths. Measurement performance is critically important at baseband frequencies, because signal degradation occuring here is typically not recoverable elsewhere in the system. As a result, test requirements for baseband signals and circuits often demand a level of performance that only a high-performance, low-frequency signal analyzer such as the HP 3585A can provide. Frequency Specifications: Measurement Range: 20 Hz to 40.1 MHz Displayed Range: Frequency Span: 0 Hz to 40.1 MHz Settable with 0.1 Hz resolution. 10 Hz to 40 MHz in 1, 2, 5 steps Accuracy: -0% + 0.2% of Frequency Span setting Marker: Readout Accuracy: ±0.2% of Frequency Span ± Resolution Bandwidth Counter Accuracy: ±0.3 Hz ±1 x 10-7/month of counted frequency for a signal 20 dB greater than other signals and noise in the IF filter skirts. Manual Frequency Accuracy: ±0.1 Hz ±1 x 10-7/month using the internal reference.Resolution: Resolution Bandwidths: 3 dB bandwidths of 3 Hz to 30 kHz in a 1, 3, 10 sequence Accuracy: ±20% at the 3 dB points Sensitivity (Shape Factor): 60 dB/3 dB < 11:1 Amplitude Specifications: Measurement Range: Terminated (50/75 Ω) Input: -137 dBm to +30 dBm or equivalent level in dBV or volts High Impedance (1 MΩ) Input: 31 nV to 22 V Displayed Range: Vertical Scale: 10 division CRT settable to 10, 5, 2, and 1 dB/division relative to the Reference Level (which is represented by the top graticule line) Input Range: -25 dBm to +30 dBm in 5 dB steps Reference Level (relative to Input Range): -100 dB to +10 dB Marker Amplitude Accuracy: Midscreen at the Reference Level: Use Reference Level accuracy from +30 dBm to -115 dBm, add Amplitude Linearity below -115 dBm. Anywhere on Screen: Add Reference Level Accuracy, Amplitude Linearity and Frequency Response Dynamic Range Specifications: Spurious Responses (image, out of band, and harmonic distortion): 50/75 Ω Input: < -80 dB referred to a single signal equal to or less than Input Range 1 MΩ Input: < -80 dB except second harmonic distortion < -70 dB Intermodulation Distortion: 50/75 Ω Input: < -80 dB referred to the larger of two signals each 6 dB below Range except 2nd order IM from 10 Mhz to 40 MHz < -70 dB 1 MΩ Input: < -70 dB Residual Responses (no signal at input): < -120 dBm using -25 dBm range Residual Phase Noise (typical at 40 MHz, -10 dBm input): 5 kHz Offset: -112 dBc/Hz 100 kHz Offset: -120 dBc/Hz Sweep Specifications: Modes: Continuous, single, or manual Trigger: Free Run, Line, or External Time: 0.2 s full sweep to 200 s/Hz of Frequency Span (swept time excluding auto calibration cycles) Input Specifications: Signal Inputs: 50/75 Ω: 26 dB return loss, BNC connector 1 MΩ: ±3% shunted by 14 dB return loss Probe Power: +15 Vdc, -12.6 Vdc; 150 mA max. IF: 350 kHz, -11 dBV to -15 dBV at the reference level Video: 10 V at the reference level Frequency Reference: 10.000 MHz ±1 x 10-7/month, +10 dBm into 50 Ω HP-IB Interface Functions: Sh1, An1, T6, L4, SR1, RL1, TP0, DC1, DT1, C0 General Specifications: Dimensions: 9" H x 16.75" W x 25" D (229 mm x 426 mm x 6353 mm) Weight: 88 lbs. (39.9 kg) Power Requirements: 115 V (+11%, -25%), 48 - 440 Hz. 230 V (+11%, -18%), 48 - 66 Hz. 180 watts, 3 A max. Warm-Up Time: 20 minutes at ambient temperature Environmental: Temperature - Operating: 0°C to 55°C Humidity: < 95% RH except 300 Hz BW < 40% RH For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $75.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination. Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.: (1) Are you the end-user of this item? (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name. (3) What is the ultimate country destination? 02/08/19

Related Items